MTU Onsite Energy's natural gas generator sets are cutting-edge technology that offer combined heat and power (CHP), and combined heat, power and cooling (CHPC) solutions to generate power. Our products combine the highest performance with the lowest emissions in the 128 kWe - 2,535 kWe electrical power range.
MTU Diesel Engines. Spare Parts Catalogs, Service Manuals, Operation and Maintenance Manuals. Spare parts catalogs and manuals are available for the following MTU diesel models: Engine Model. Catalog / Manual. Engine Model: Catalog / Manual. 20V4000 G22-G82. Operation and maintenance manual. Spare parts catalog. MTU Onsite Energy Diesel Product Brochure Reference Page. 60 Hz Generator Sets – Gas Standby (continued). MTU 20V4000 DS2500 (2,500 kW). The following table gives paper specifications used by MTU Onsite Energy for each section of. With reliable MTU engines, MTU Onsite Energy delivers the benefits of.
Therefore, our natural gas powered CHP systems represent the. Public buildings and residential utilities. Industrial & Manufacturing. Mission critical applications. Electrical power range: 128 - 420 kWe Minimum space.
Maximum efficiency. Features of the extended Series 400:. Dungeon masters guide 3 5. Flexible scope of supply: All systems are available in open or soundproofed designs, either for building into existing facilities or as turnkey systems. Modular design: The generator set can be configured to your specific requirements. All modules are designed to work together in perfect harmony. Standard interfaces and components enable our systems to be installed quickly and maintained easily.
Unceasing design improvement and development work for over 35 years. Best overall efficiency in this power range (up to 93%) Options:. Basic model for power generation only. Basic model complete with heat cabinet for combined-heat-and-power generation. Heat extraction from engine coolant and mixture coolant (acoustic enclosure optional). Basic model complete with heat cabinet and exhaust heat exchanger (acoustic enclosure optional).
Heat extraction from engine coolant, mixture coolant and exhaust. Gas engine Advanced and proven Series 400, optimized for natural gas, biogas and other special gases. Specially developed combustion chambers ensure top efficiency in its performance class.
Generator Optimally tailored to the engine and made by renowned manufacturers, combining maximum reliability with top efficiency. Ignition system The cylinder-specific ignition system allows for efficiency-optimized operation of all cylinders, even with variable CH4 content. The ignition voltage display makes it easy to check the condition of the spark plugs.
Mixture cooler Large-surface, two-stage mixture cooler for improved engine performance and heat utilization. Knock detection and protection Cylinder-specific to protect the engine from abnormal operating conditions and guarantee reliable operation even when using gas with a low methane count. MTU Module Control (MMC) Comprises the engine control, activation and power supply to all the module’s auxiliary drives along with the key system control functions. All the auxiliary drives necessary for the CHP system can be operated from here. MTU generator power section Connects the system to the mains supply and integrates the generator’s synchronization and fuse protection functions. The power cable connection between the generator and power section is factory wired. Gas engine Advanced and proven Series 400 gas engine, optimized for natural gas use.
Combustion chambers ensure the highest level of efficiency in this performance category. For 60 Hz-Aplications the engine is rotating with a speed of 1800 rpm instead of 1500 rpm.
Mtu Engines Usa
Therefore a gear box is not necessary. Generator Optimally tailored to the engine and made by renowned manufacturers, the generator ensures a high level of reliability with the best degree of efficiency. Ignition system Ignition systems for individual cylinders allow for the most efficient level of operation for all cylinders, even with variable CH4 content. The ignition voltage display gives customers information about the state of the spark plugs. Mixture cooler The two-stage mixture cooler with large surface area improves engine performance and heat utilization. Knock detection Cylinder-specific knock detection and regulation protects the engine from abnormal operating conditions and guarantees safe operation even with natural gas with a low methane number.
Crank-case ventilation High quality crank-case ventilation minimizes deposits in intake tract and combustion chamber and guarantees a continuously high level of performance. MTU Module Control (MMC) The MTU Module Control (MMC) contains all the important functions necessary for controlling the system. All the auxiliary drives required for the CHP system can be operated from here. The integrated power circuitry minimizes the need for cabling on site. Generator Optimally tailored to the engine and made by renowned manufacturers, the generator ensures a high level of reliability with the best degree of efficiency.
Mtu Diesel Engine Specifications
Gear Box For 60 Hz-Applications a gear box increases the engine speed of 1500 rpm to 1800 rpm at the generator. The gear box is perfectly adjusted to the engine and the generator. Gas engine Advanced and proven Series 4000 gas engine, optimized for natural gas use. Combustion chambers ensure the highest level of efficiency in this performance category. Ignition system Ignition systems for individual cylinders allow for the most efficient level of operation for all cylinders, even with variable CH4 content. Mixture cooler The two-stage mixture cooler with large surface area improves engine performance and heat utilization.
Mtu 4000 Engine
Knock detection Cylinder-specific knock detection and regulation protects the engine from abnormal operating conditions and guarantees safe operation even with natural gas with a low methane number. Crank-case ventilation High quality crank-case ventilation minimizes deposits in intake tract and combustion chamber and guarantees a continuously high level of performance. 50 Hz / 776 - 2,535 kWe.
Gas engine Advanced and proven Series 4000 gas engine, optimized for natural gas use. Combustion chambers ensure the highest level of efficiency in this performance category. Generator Optimally tailored to the engine and made by renowned manufacturers, the generator ensures a high level of reliability with the best degree of efficiency. Ignition system Ignition systems for individual cylinders allow for the most efficient level of operation for all cylinders, even with variable CH4 content. Mixture cooler The two-stage mixture cooler with large surface area improves engine performance and heat utilization. Knock detection Cylinder-specific knock detection and regulation protects the engine from abnormal operating conditions and guarantees safe operation even with natural gas containing low levels of methane. Crank-case ventilation High quality crank-case ventilation minimizes deposits in intake tract and combustion chamber and guarantees a continuously high level of performance.
Genset Type Output Electr. 2 Exhaust 3 Low Temp. KW e kW th kW th (°C) kW th (°C) MTU 8V4000 GS 776 401 422 (120) 47 (40) MTU 8V4000 GS 854 443 448 (120) 49 (40) MTU 8V4000 GS 1,012 475 461 (120) 69 (43) MTU 12V4000 GS 1,169 632 638 (120) 43 (53) MTU 12V4000 GS 1,523 712 691 (120) 104 (43) MTU 16V4000 GS 1,718 974 821 (120) 113 (40) MTU 16V4000 GS 1,999 950 928 (120) 125 (43) MTU 16V4000 GS 2,028 965 936 (120) 127 (43) MTU 20V4000 GS 2,145 1,161 1,078 (120) 142 (40) MTU 20V4000 GS 2,535 1,186 1,212 (120) 176 (43).